OGI Gas detection cameras

Products

OGI portable and fixed gas detection cameras…

gasviewer

OGI PORTABLE CAMERA
GASVIEWER GV-P-3234

To see gas leaks invisible to the naked eyes. For fugitive emissions detection, localization, visualization, and quantification (optional). Gases appear in real time as fumes on the built-in screen.
Approved as Smart LDAR Equipment in EPA method 21 and EN15446 regulations.
Safe for hazardous areas

Cooled detector technology allows to find leaks as low as 0,35 gr/hr for CH4 at 2 m distance

• Color
• Infra-red
• Enhanced gas detection
• Thermography

Record your leaks picture or video on the embedded 64 GB SD card. Then, download the videos through USB or Wifi to your computer.

• WIFI HOTSPOT: to connect an external screen, for video streaming in real time or our quantification tablet (optional).
• BLUETOOTH: to connect various measuring equipment (optional).
• GPS coordinates: to record the GPS location of each leak at the bottom of the screen.

• Ex ic nA nC IIC T6 Gc
• Ex ic IIIC T85 C Dc
• IP 65
— Very low operating costs

400+ compounds such as: Methane, Acetic acid, Benzene, Butadiene, Butene, Butane, Dimethyl-Benzene, Ethane, Ethylene, Ethyl benzene, Ethylene oxide, Hexane, Heptane, Isobutylene, Isopropyl alcohol, Isoprene, Methanol, MEK Methyl Ethyl Ketone, Octane, Pentene, Propane, Propanol

gasviewer

OGI PORTABLE CAMERA
GASVIEWER GV-P-714

To see gas leaks invisible to the naked eyes. For fugitive emissions detection, localization, visualization and quantification (optional). Gases appear in real time as fumes on the attached windows tablet screen. Approved as Smart LDAR Equipment in EPA. method 21 and EN15446 regulations. Safe for hazardous areas.

Uncooled detector technology allows to find leaks
as low as 6,3 gr/hr for methanol at 2 m distance.

• Color
• Infra-red
• Enhanced gas detection
• Thermography

Record your leaks picture or video on the attached
tablet 256 GB hard drive. Then, download the
videos through Wifi to your computer.

• Thermography
• Colorization of the leaking gas
• Estimation of the leaking rate

• Camera : Atex II B 3G Ex NA II B Gc
• Tablet : Atex II 3G Ex ic IIC T4 Gc
• IP 65 for the camera and tablet

CH4, SO2 and VOC’s , NH3, SF6, Methanol, cooling gases (CFC, HCFC)…
gasviewer

QUANTIFICATION TABLET GASVIEWER GV-Q-3234

A simple and user friendly way to estimate in real time, from a distance, the flow rate from the leaks found with our portable camera GV-P-3234.

• Flow rate estimate in gr/h.
• Can quantify all the gases detected by our GV -P-3234.
• Estimates flow rate in real time through wi-fi connection to our GV-P-3234 OGI camera.

• 29.46 cm / 11.6“ (1920 x 1080) FHD LCD Panel • Capacitive Multi-Touch • Optical, sunlight-readable display

• M2-SATA SSD 256 GB (extended temperature range)

• TIECEX :
– Ex ic IIC T4 Gc IP64
– Ex ic IIIB T135°C Dc IP64

gasviewer

OGI FIXED COOLED CAMERA
GASVIEWER GV-F-3234

• 24/7 on site gas leak monitoring.
• Real time gas cloud colorization and quantification.
• Full turnkey solution including field junction box, control room hardware, alarms and connection to DCS.
• Safe for hazardous area (Atex zones 1 and 2).

As low as 0.3 gr/sec CH4 at 125 m or 0,5 gr/sec CH4 at 250 m.

• Automatic visual and audible alarm on system screen in control room.
• Sending SMS or email to the person on call (optional).
• Through your DCS (optional).

• From camera to control room: fiber optic or wireless (optional).
• From system server located in your control room to your DCS: Modbus or dry contact (both optional).

• Automatic video recording starts with every alarm and lasts the time of the alarm.
• Additional recording time can be set up as per customer requirement (24/7 during X days for example).
• Videos are stored on the system hard drive. A user-friendly interface allows easy retrieval and play back for later analysis.

ATEX II 2G Ex db IIC T6 Gb, zone 1 available as option.

System server and software can handle multiple GV-F-3234.

400+ compounds such as: Methane, Acetic acid, Benzene, Butadiene, Butene, Butane, Dimethyl-Benzene, Ethane, Ethylene, Ethyl benzene, Ethylene oxide, Hexane, Heptane, Isobutylene, Isopropyl alcohol, Isoprene, Methanol, MEK Methyl Ethyl Ketone, Octane, Pentene, Propane, Propanol

gasviewer

OGI FIXED UNCOOLED CAMERA GASVIEWER GV-F-714

• 24/7 on site gas leak monitoring.
• Real time gas cloud colorization and quantification.
• Full turnkey solution including field junction box, control room hardware, alarms and connection to DCS.
• Safe for hazardous area (Atex zones 1 and 2).

As low as 0.5 gr/sec CH4 at 100 m or 0,3 gr/sec CH4 at 50 m.

• Automatic visual and audible alarm on system screen in control room.
• Sending SMS or email to the person on call (optional).
• Through your DCS (optional).

• From camera to control room: fiber optic or wireless (optional).
• From system server located in your control room to your DCS: Modbus or dry contact (both optional).

• Automatic video recording starts with every alarm and lasts the time of the alarm.
• Additional recording time can be set up as per customer requirement (24/7 during x days for example).
• Videos are stored on the system hard drive. A userfriendly interface allows easy retrieval and play back for later analysis.

ATEX II 3G Ex ec IIC T4 Gc, zone 1 available as option.

System server and software can handle multiple GV-F-714.

CH4, SO2 and VOC’s , NH3, SF6, Methanol, cooling gases (CFC, HCFC)…